Showcaller AI gives you Allen & Heath SQ remote control for the SQ-5, SQ-6 and SQ-7, over the network, by voice or chat. So you keep your hands free instead of holding a tablet. For example, you can mute the audience mics for the video playback. Then you can bring up the panel’s channels or add a little lectern into the in-ear mix. You can also ride a DCA or recall the scene for the next session.

Showcaller connects to the console through the Bridge App on your show network. It uses the SQ’s own MIDI control over the network. On inputs, it controls mutes and faders into the main LR mix. It also rides the Main LR master and the Aux/Mix masters (1-12). Showcaller also sets each input’s send to an Aux/Mix and to the four FX engines, plus the FX return levels. Beyond that, it handles the eight DCAs, the eight mute groups and the Soft Keys. Finally, it recalls scenes 1 to 300.

After a change, Showcaller reads the console back. It reports success only when the SQ agrees on mute states, fader levels and send levels in dB. We measured the level read-backs on a real SQ-5, and they matched. A scene recall replaces the live mix, so Showcaller asks you to confirm it first.

Two console settings matter. First, the SQ’s MIDI channel must match the one you set in Showcaller. Second, set the console’s NRPN fader law to Linear Taper, because that keeps levels in dB accurate. The FAQ below explains why. You can find the console itself on the [Allen & Heath SQ](https://www.allen-heath.com/hardware/sq/sq-7/) product page.

## Questions about Allen & Heath SQ control

### Which consoles are supported?

Showcaller supports the Allen & Heath SQ-5, SQ-6 and SQ-7.

### What do I need to set up on the console?

Go to Utility > General > MIDI on the console. Note the SQ’s MIDI channel, which is 1 by default. Then set the NRPN fader law to Linear Taper. Showcaller needs the console’s IP address (TCP port 51325) and the matching MIDI channel. You also need the Showcaller Bridge App on a computer on the same network.

### Which plan includes which Tool Functions?

Starter includes Device Diagnostics, Channel Fader & Mute, and Main & Aux Outputs (13 Tool Functions). Pro adds Mix Sends & FX Routing and DCA & Mute Groups (12 more). Enterprise then adds Scene & Soft Keys (2 more). Each plan includes every Tool Function of the plans below it. See [pricing](/pricing/) for the plans.

### Why does the fader law matter?

Showcaller converts dB values using the Linear Taper law. However, the console may use another fader law. In that case, the levels Showcaller sets and reads will not match what you asked for.

### Does Showcaller confirm the change on the console?

Yes. Showcaller reads mutes and levels back from the SQ after each change. When they do not match, it tells you.